Feature Description

Using this data logger, you will be able to monitor and manage your EMS once the installation has been completed. With simplicity in mind there is only one toggle switch and one SMA aerial connection.

  • 3G, 4G, LTE and BLE connectivity.
  • Sensor data stored in flash memory on board as a backup.
  • Network synchronised utilising universal co-ordinate time (UTC) for all data points.
  • User customisable with site set up tools via Android app.
  • Strong and durable casing to protect the internal hardware.
  • The standard aerial is vandal resistant.
Certification

The Ontoto EMS has been designed to comply to Australian Standards:

  • AS/NZS 3820:2009 for low voltage battery powered devices.
Device Specifications
Product Features
  • 3G/4G Mobile network connectivity.
  • Solar Powered with battery backup.
  • Sampling and reporting frequencies every 10 minutes.
  • No proprietary software to receive or access the data.
  • Complimentary web portal for device and data management.
  • Supports 14 different sensor packages.
  • Designed and made in Australia.
Technical Specifications
  • Operational temperature range from -20 to 80 degrees C.
SpecificationDiameter: 10cm
Height: 34cm
Solar RadiationRange: 0-1750W/m2
Resolution: 1W/m2
Accuracy: ±5%
RainfallRange: 0-125 mm/hr
Resolution: 0.017mm
Accuracy:±5% of measurement from 0 to 50 mm/h
Vapour PressureRange: 0 to 47 kPa
Resolution: 0.01 kPa
Accuracy: Varies with temperature and humidity, ±0.2 kPa typical below 40°C
HumidityRange: 0-100%
Resolution: 0.1% RH
Accuracy: ±3%
TemperatureRange: -40 to 50°C
Resolution: 0.1°C
Accuracy: ±0.6°C
Humidity Sensor TemperatureRange: -40 to 50°C
Resolution: 0.1°C
Accuracy: ±1.0 °C
Barometric PressureRange: 50-110 kPa
Resolution: 00.01 kPa
Accuracy: ±0.1 kPa
Wind DirectionRange: 0-359°
Resolution: 1°
Accuracy: ± 5°
Wind SpeedRange: 0 to 40 m/s
Resolution: 0.01 m/s
Accuracy: the greater of 0.3m/s or 3% of measurement
Wind GustRange: 0 to 40 m/s
Resolution: 0.01 m/s
Accuracy: the greater of 0.3m/s or 3% of measurement
Lightning Strike CountRange: 0-65,535
Strikes Resolution: 1
strike Accuracy: variable with distance, >25% detection at < 10km
Lightning Average DistanceRange: 0-40km,
Resolution: 3km
Accuracy Variable
Sensor Parameters
  • minimum wind direction
  • average wind direction
  • maximum wind direction
  • minimum wind speed
  • average wind speed
  • maximum wind speed
  • temperature
  • humidity
  • air pressure
  • rainfall
  • solar radiation
  • UV intensity
  • maximum noise
  • minimum noise
  • average noise
  • 5 particle concentration
  • PM10 particle concentration
Battery Specifications

The provided battery pack is comprised a LiPo battery

  • Voltage: 3.6 V
  • Capacity: 10,000 mAH
  • Temperature range: -55°C to +85°C